HPLC Column, RP C4 Butyl, 5um, 2.1mm ID x 150mm Length, 100A. Cogent Brand. 1 EA.
Additional Information:
Cogent RP C4™ is a reversed-phase HPLC stationary phase designed for the separation of hydrophobic and neutral compounds where less retention is desired than with traditional C8 or C18 phases. Manufactured using a four-carbon butyl ligand bonded to ultra-high purity silica and fully double end capped, this stationary phase provides reproducible chromatographic performance and is widely used as an alternative in USP methods requiring L26 chemistry. Its reduced hydrophobicity compared to longer-chain bonded phases makes it particularly useful for rapid analyses, routine testing, and method development.
68504-15P-2 is an HPLC column packed with 5 µm RP C4™ particles featuring a 100 Å pore size in a 2.1 mm ID x 150 mm format. This narrow-bore configuration combines excellent chromatographic resolution with reduced solvent consumption and compatibility with LC-MS instrumentation. The 150 mm length provides increased peak capacity and resolving power compared to shorter column formats, while the 5 µm particles provide robust performance with moderate backpressure. Typical operating flow rates are approximately 0.2–0.3 mL/min. Standard HPLC systems used with 2.1 mm ID columns must be capable of precise and reproducible low-flow operation.
This column is commonly used for hydrophobic and neutral compounds in reversed-phase HPLC when reduced retention is desirable. Compared to C8 phases, RP C4™ typically provides lower retention, making it useful for compounds that may otherwise be excessively retained on more hydrophobic stationary phases. The 2.1 mm ID format is especially popular for LC-MS methods due to its low solvent consumption, enhanced sensitivity, and efficient analyte transfer to the mass spectrometer.
Key Benefits
RP C4™ stationary phase
USP L26 equivalent chemistry
Butyl bonded phase
Fully double end capped
Ultra-high purity silica support
Less retention than C8 phases
Suitable for rapid analyses
Reduced solvent consumption
5 µm particle size
Excellent for LC-MS applications
Typical Applications
USP L26 methods
LC-MS methods
Method development
Method scouting
Hydrophobic compound analysis
Neutral compound analysis
Reversed-phase HPLC
Pharmaceutical analysis
Quality control testing
Research and development
Specifications
Product Type: HPLC Column
Stationary Phase: RP C4™
USP Classification: L26
Chromatography Mode: Reversed Phase
Bonded Phase: Butyl (C4)
Endcapping: Fully Double End Capped
Particle Size: 5 µm
Pore Size: 100 Å
Column Dimensions: 2.1 mm ID x 150 mm
Length: 150 mm
Typical Flow Rate: 0.2–0.3 mL/min
Brand: Cogent
Important Notes
Designed for hydrophobic and neutral compounds
Provides less retention than C8 stationary phases
Suitable for rapid reversed-phase separations
The 2.1 mm ID format is commonly used for LC-MS applications
Standard HPLC systems must be capable of reliable operation at approximately 0.2–0.3 mL/min
Detector flow cells should be optimized for low-volume, narrow-bore chromatography
The 150 mm length provides greater resolution and peak capacity than shorter column formats
5 µm particles provide robust performance with moderate operating pressures
Fully double end capped to minimize secondary interactions
Frequently used for method development and scouting studies